The following additionally applies

Shielded lines 

Joins in the shield can cause problems with regard to noise radiation and interference immunity. Consequently, distinctions have to be drawn between the following types:

Coaxial lines 

CVBS lines 

HSD lines 

Optical fibre cable: 

NOTE: Fibre-optic cables are colored differently as follows:
IMPORTANT:
  • Optical fibres are permitted to show only one  junction point (bridge). Replace optical fibres if necessary
  • Smallest permissible bending radius is 25 mm
  • Avoid effects of heat ≥ 85 °

Treating cables and fibre-optic cables  . See 61 13... CUTTING OFF, STRIPPING INSULATION AND CUTTING OPTICAL FIBRES TO LENGTH  or 61 13... CRIMPING OPTICAL FIBRES .

FlexRay: 

It is possible to repair the FlexRay. In the event of damage, the cables can be joined with conventional BUTT CONNECTORS AND HEAT-SHRINK TUBING .

NOTE:
  • FlexRay lines may only reveal one separation point (bride); renew complete line if necessary
  • The cable is a twisted cable. If possible, maintain twisted cable after repair

Airbag lines: 

REPAIRING AIRBAG CABLES