LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> 535i GT >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Anti-Theft Systems >> General Electrical System - Repair >> Wiring Harness >> 61 00... Notes on handling wiring harnesses and cables >> The following additionally applies

The following additionally applies

Shielded lines 

Joins in the shield can cause problems with regard to noise radiation and interference immunity. Consequently, distinctions have to be drawn between the following types:

Coaxial lines 

CVBS lines 

HSD lines 

Optical fibre cable: 

NOTE: Fibre-optic cables are colored differently as follows:
IMPORTANT:
  • Optical fibres are permitted to show only one  junction point (bridge). Replace optical fibres if necessary
  • Smallest permissible bending radius is 25 mm
  • Avoid effects of heat ≥ 85 °

TREATING CABLES AND FIBRE-OPTIC CABLES 

FlexRay: 

It is possible to repair the FlexRay. In the event of damage, the cables can be joined with conventional butt connectors and heat-shrink tubing  . See 61 13... CUTTING OFF, STRIPPING INSULATION AND CUTTING OPTICAL FIBRES TO LENGTH  or 61 13... CRIMPING OPTICAL FIBRES .

NOTE:
  • FlexRay lines may only reveal one  separation point (bride); renew complete line if necessary
  • The cable is a twisted cable. If possible, maintain twisted cable after repair

Airbag lines: 

REPAIRING AIRBAG CABLES .