Condition for fault identification
Test condition:
The fault is recognized when the leak diagnosis pump's current fails to reach a specified limit within a time window defined in the program map.
Potential problem source(s):
- Defective wiring harness
- DMTL defective
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- Ambient temperature between 3.8 °C and 35.3 °C
Time condition:
- 10 min. in shutdown phase
Other conditions:
- Cold start (engine temperature max. 6 °C above ambient temperature)
- Then drive at least 600 sec.
- Remain stationary for at least 30 sec. at idle
- Drive over 45 km/h for at least 300 sec. (total)
- Fuel level between 15% and 85% of maximum tank capacity
- Then switch off engine, Terminal 15 off
- Wait roughly 10 min. until diagnostic routine is completed