Condition for fault identification
Test condition:
The fault is recognized when the oil condition sensor reports a fault.
Potential problem source(s):
- Defect in plugs or wiring harness between oil condition sensor and DME
- Oil condition sensor defective
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine on
- Engine speed above 5000 RPM
- No BSD fault