LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2013 >> 320xi >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Self Diagnosis - Diagnostic Trouble Codes (N20 & N26) >> Fault Code Tests >> DTC P2196: BMW DTC 128301; DME -- O2 Sensor Signal Biased/Stuck Rich (Bank 1 Sensor 1) >> Action in service

Action in service

Secondary fault, rectify faults relating to the following components or functions:

Check exhaust system in the area of the oxygen sensor before catalytic converter for tightness.

Check crankcase ventilation.

Check lines and plug connections between the following components:

Replace oxygen sensor before catalytic converter.

Renew oxygen sensor after catalytic converter.