Condition for fault identification
Test condition:
The fault is recognized when the engine is turning over and camshaft signals have been present.
Potential problem source(s):
- Defect in wiring harness between DME and camshaft position sensor
- Incorrect gap between camshaft position sensor and camshaft sensor reluctor ring
- Sensor contaminated or defective
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine ON