LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2012 >> X6 50i >> Repair and Diagnosis >> External Pages >> Different car >> Section 1998 (Self Diagnosis - Diagnostic Trouble Codes - DTC P0035 - DTC P0480 (N63 & S63)) >> Diagnostic Trouble Codes (DTCS) MSD85 - Bn2020 >> DTC P2415, BMW Hex Code 0x128C01, BMW Code 1215489: O2 Sensor Exhaust Sample Error (Bank 2 Sensor 1) >> Monitoring criteria

Monitoring criteria

WARNING: This page does not describe the selected car, but rather 53 other vehicles, including the 2013 BMW X6 M, 2013 BMW X5 M, 2013 BMW M6, 2013 BMW M5, and 2013 BMW Alpina. However, it is still accessible from the selected car via links, so may be relevant.

The fault is recognized when voltage at the pre-catalyst oxygen sensor 2 is > 4.8 V (lean) under partial or full load.

Potential problem source(s):

-Oxygen sensor not screwed in correctly