Home >> BMW >> 2012 >> X6 50i >> Repair and Diagnosis >> External Pages >> Different car >> Section 1998 (Self Diagnosis - Diagnostic Trouble Codes - DTC P0035 - DTC P0480 (N63 & S63)) >> Diagnostic Trouble Codes (DTCS) MSD85 - Bn2020 >> DTC P2273, BMW Hex Code 0x12A201, BMW Code 1221121: O2 Sensor Signal Biased/Stuck Rich (Bank 2 Sensor 2) >> Monitoring criteria

Monitoring criteria

WARNING: This page does not describe the selected car, but rather 53 other vehicles, including the 2013 BMW X6 M, 2013 BMW X5 M, 2013 BMW M6, 2013 BMW M5, and 2013 BMW Alpina. However, it is still accessible from the selected car via links, so may be relevant.

The fault is recognized when the voltage of the oxygen sensor 2 behind the catalytic converter is below 0.2 V (too lean). Potential problem source(s): Oxygen sensor 2 behind catalytic converter defective

-Leak in exhaust system upstream of oxygen sensor 2 behind catalytic converter

-Defect in wiring harness to oxygen sensor 2 behind