12 42 550 Replacing battery positive lead between starter, alternator and battery positive terminal (N63)
Necessary preliminary tasks:
- Read out fault memory of DME control unit
- Turn off ignition
- Disconnect BATTERY NEGATIVE LEAD
- Remove RIGHT INTERCOOLER
- Remove INTAKE AIR MANIFOLD
Open cover.
Release screw (1).
Tightening torque: 12 42 3AZ .
Remove battery positive lead (2) from battery positive terminal.
Release clamp (1).
Tightening torque: 13 71 8AZ .
Release clamp (2).
Replace clamp (2).
Remove left charge-air duct (3).
Check gasket on turbocharger, replacing if necessary.
Detach hose (1) from clean-air pipe.
Release screw (2).
Tightening torque: 13 71 1AZ .
Detach clean-air pipe (3) in direction of travel from turbocharger.
Check seal on clean-air pipe, replacing if necessary.
Detach cover (1) and release nut underneath.
Tightening torque: 12 42 1AZ .
Installation:
Reinstall cover (1) without fail.
Risk of short circuits!
Disconnect battery positive lead (2) from alternator.
Release battery positive lead (1) from retainers (2).
Release battery positive lead (1) from retainer (2).
Release screws (1).
Tightening torque: 12 42 7AZ .
Release nut (2) on starter.
Tightening torque: 12 42 2AZ .
Disconnect battery positive lead (3).
Check stored fault message.
Delete fault memory.