12 42 500 Replacing positive battery cable between starter motor, alternator and positive battery connection point (N47 D20 O1)
Necessary preliminary work:
- Read out the fault memory of the DME control unit.
- Switch off ignition.
- Disconnect BATTERY EARTH LEAD .
- Remove INTAKE FILTER HOUSING .
- Remove UNDERBODY PROTECTION
Fold back cover (1).
Release nut underneath.
Tightening torque 12 52 4AZ .
Remove positive battery cable from battery positive terminal.
Release positive battery lead(1) from acoustic cover (3).
Slacken nut (1).
Tightening torque 12 52 2AZ .
Disconnect positive battery cable from alternator.
Release positive battery lead from retainer (2).
Release retainers (1) and detach positive battery lead from guide.
Release nut (1) on starter motor.
Tightening torque 12 52 3AZ .
Disconnect positive battery cable from starter motor.
Release positive battery cable from retainers (2).
Feed out positive battery cable and remove.
NOTE:
Reassemble the vehicle.
Check stored fault messages.
Delete fault memory.
Check stored fault messages.
Delete fault memory.