64 50... Safety information for handling tetrafluorethane refrigerant R134a
WARNING:
Danger of injury. Refrigerant circuit is under high pressure! Work on the refrigerant circuit may only be carried out by experts!
Always draw off refrigerant BEFORE any repair work is started on the refrigerant circuit.
The refrigerant circuit is depressurized after drawing off!
IMPORTANT:
It is absolutely essential to read and observe the manufacturer's operating instructions for the A/C service unit used.
Protective measures:
- Wear safety goggles
- Wear oil-resistant protective gloves
- Do not smoke!
- Observe country-specific safety regulations.
First aid measures:
- Eye contact: In the event of contact with the eyes, rinse immediately with plenty of running water and consult an ophthalmologist.
- Skin contact: In the event of contact with skin, remove affected clothing immediately and rinse with plenty of water.
- After inhalation: If refrigerant vapors are inhaled in greater concentrations, remove the person affected to an area of fresh air and keep them under supervision. Call for a doctor. If breathing problems are experienced, breathe additional oxygen. If the person affected is breathing with difficulty or has stopped breathing, incline the person's head at the neck and administer the kiss of life.