64 50 010 Drawing off, evacuating and filling heating and air conditioning system (R134a)

WARNING: Follow all applicable SAFETY INFORMATION .
IMPORTANT:

The suction-side filling line of the refrigerant circuit is omitted from the engine versions of model series E9X and E8X.

This is replaced by a direction connection on the expansion valve.

Shown on N54 engine by way of example.

Direct connection of filling adapter (1) on the expansion valve is shown.

NOTE: Make sure filling hose is laid without kinks.
Fig 1: Identifying Filling Adapter
G06851977Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Risk of damage!
Only BMW-approved R134a refrigerant may be used.
Restart engine only when the air conditioning system has been correctly filled.
IMPORTANT: Risk of damage!
Carefully move the climate service station!
Comply with the operating instructions and service interval for the A/C service station!
Make sure that the hoses of the A/C service station are drained after the drawing off or filling procedure!
The climate service station contains highly sensitive components, such as scales. These components will be damaged due to improper handling, such as fast driving over a bump. This will result in a significant reduction of the measuring accuracy when drawing off and filling.
Fig 2: Evacuating Heating And Air Conditioning System
G10022797Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: The vehicle must be parked on the floor during all drawing off, evacuation and filling procedures!
Filling a raised vehicle will result in insufficient filling levels.
NOTE: In case of complaints, carry out a heating and air conditioning performance test!
If the system fails the test, draw off, evacuate and fill the heating and air conditioning system in accordance with the operating instructions of the relevant service station.
Service interval of service station must be adhered to.

Instructions for drawing off heating and air conditioning system: 

To help separation of refrigerant and refrigerant oil, run engine at low speed (800-1200 RPM) and with heating and air conditioning system turned on for a few minutes.

The limits the entrainment of refrigerant oil while it is drawn off.

Drawn-off refrigerant oil must be changed and reintroduced via the service station.

During drawing off, set blower of heating and air-conditioning unit to middle blower speed. This ensures that drawing off is more effective since the pressure on the low pressure side increases.

Recycling:

Dispose of drawn-off refrigerant oil as hazardous waste.

Observe country-specific waste disposal regulations.

Instructions for evacuating heating and air conditioning system: 

Before each filling, evacuate the refrigerant system.

Observe an evacuation time of at least 30 minutes  .

The evacuation procedure removes all traces of ambient air, water vapor and any other gases present from the heating and air conditioning system. This enables subsequent system filling with refrigerant.

If the vacuum does not remain stable when the system is off, run the procedure for leaks in the refrigerant circuit.

During evacuation, set blower of heating and air-conditioning unit to middle blower speed. This ensures that evacuation is more effective since the pressure on the low pressure side increases.

Instructions for filling heating and air conditioning system: 

Before filling with refrigerant, replace the refrigerant oil entrained during drawing off.

Also top up any lost fluid as indicated in the table:

Loss of R134a refrigerant 

Table 1  indicates the permitted loss of refrigerant after a specific period of time. There is no leak, refrigerant oil may not be topped up.

Table 2  indicates the amount of refrigerant oil must be topped up with an unapproved loss of refrigerant due to a leak after a specific period of time.

Different cases: 

  1. Loss of refrigerant per Table 1 is not exceeded 
    • Top up lost R134a refrigerant
    • It is not permitted  to top up the refrigerant oil
  2. Loss of refrigerant per Table 1  is exceeded
    • Top up lost R134a refrigerant
    • refrigerant oil must be topped up additionally  per Table 2 
REFRIGERANT OIL SPECIFICATION

Number of years since last filling  0 - 1 1 - 2 2 - 3 3 - 4 4 - 5
Permissible loss [g] → no need to top up refrigerant oil  ≤ 30 ≤ 60 ≤ 90 ≤ 120 ≤ 150
REFRIGERANT OIL SPECIFICATION

Number of years since last filling R134a loss of coolant [g] Top up quantity refrigerant oil
0 -1 - <120 0
120 - 150 10
>150 20
1 - 2 - <180 0
180 - 210 10
>210 20
2 - 3 - <240 0
240 - 270 10
>270 20
3 - 4 - <300 0
300 - 330 10
>330 20
4 - 5 - <360 10
>360 20

Follow NOTES FOR OPENING AND PART REPLACEMENT in refrigerant circuit.

Depending on the type of component replaced on the heating and air conditioning system, it may be necessary to the top up the refrigerant oil, even if no measurable losses have occurred during drawing off. Follow the notes provided by the heating and air conditioning system manufacturer, taking account of the tolerances (and inaccuracies) indicated in the operating instructions of the relevant service station.

Information on the required refrigerant fill quantity for the entire heating and air conditioning system is contained on the type plate (1) in the engine compartment.

Fig 3: Identifying Engine Compartment Plate
G04727875Courtesy of BMW OF NORTH AMERICA, INC.

If necessary, refer to the Technical Data for CAPACITY .

Installation note: 

Reseal refrigerant filler necks on vehicle with sealing caps.