12 42 500 Replacing positive battery cable between starter motor, alternator and positive battery connection point (N54 N54T N55)
Necessary preliminary tasks:
- Read out the fault memory of the DME control unit.
- Switch off ignition.
- Disconnect BATTERY EARTH LEAD .
- Remove INTAKE PLENUM .
Remove protective cap (not shown).
Release screw, remove positive battery cable (1) from battery positive terminal.
Tightening torque 12 42 3AZ .
Remove protective cap and release nut underneath.
Tightening torque 12 42 1AZ .
Disconnect positive battery cable (1) from alternator.
Unlock connector (1) and remove.
Unfasten nut.
Tightening torque 12 42 2AZ .
Disconnect positive battery cable (2) from starter motor.
Unclip positive battery cable (1) from holder (2) and remove.
NOTE:
Check stored fault messages.
Delete fault memory.