LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2012 >> Alpina B7x >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning - Repair >> Heater With Operation >> 64 11 973 Removing and installing or replacing ozone generator (before 09/2010)

64 11 973 Removing and installing or replacing ozone generator (before 09/2010)

NOTE: The ozone generator was installed on vehicles built before 09/2010.

Necessary preliminary work: 

Disconnect plug connection (1).

Unlock ozone generator (2) in direction of arrow and remove towards front from filter housing (3).

Fig 1: Removing Ozone Generator
G06886160Courtesy of BMW OF NORTH AMERICA, INC.

Installation note: 

For purposes of clarity, illustration shows heating/air conditioning unit (1) removed.

Retaining lugs (3) on ozone generator (4) must be correctly engaged in guides on filter housing (3).

Fig 2: Identifying Heating/Air Conditioning Unit, Lugs And Ozone Generator
G06886161Courtesy of BMW OF NORTH AMERICA, INC.