Condition for fault identification
Test condition:
The fault is recognized when the voltage of the barometric-pressure sensor > 4.5 V.
Potential problem source(s):
- Internal DME fault, because barometric-pressure sensor is located in the DME ECU; sensor voltage above threshold;
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- 5 sec. after engine off
Other conditions:
- Shutdown phase