LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2012 >> 535i GT >> Repair and Diagnosis >> Engine Performance >> Ignition System >> Engine Electrical System - Repair >> Starter Lead >> 12 42 540 Replacing safety battery terminal (SBK) >> Battery in luggage compartment under floor trim panel

Battery in luggage compartment under floor trim panel

Follow instructions for disconnecting and connecting battery.

Fold back floor trim panel (1).

Lift cover (2) on battery negative lead.

Disconnect and cover battery negative lead (3).

Release nuts (4).

Remove battery cover.

Fig 1: Folding Back Floor Trim Panel
G08420110Courtesy of BMW OF NORTH AMERICA, INC.