LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2012 >> 535i Automatic Trans >> Repair and Diagnosis >> Engine Mechanical >> Cooling System (Mechanical) >> Engine - Variable Valve Timing Control System (VANOS), Intake Plenum, Turbocharger, Water Pump, Thermostat, Coolant Lines, EGR Valve, EGR Cooler, Oxygen Sensors - Repair >> Turbocharger >> N55 Engine >> 11 65 300 Adjusting electrical controller drive (wastegate valve) (N55)

11 65 300 Adjusting electrical controller drive (wastegate valve) (N55)

NOTE: Basic setting of the wastegate linkage can only be checked or adjusted using the diagnosis.
IMPORTANT: The adjusting nuts (1 and 2) may only countered by using two open-end spanners.
Using just one open-end spanner risks damaging the electrical actuator drive.

Installation note: 

Shorten adjustment travel (-).

Increase adjustment travel (+).

To ensure a reliable setting of the adjustment travel, both adjusting nuts must be marked with a colored mark.

One full turn of the adjusting nut corresponds to an adjustment travel of 0.75 mm  .

Example 1:

Actual value measured by the diagnostic function: +0.75 mm  .

Required correction: +0.75 mm: 0.75 mm  = +1.0 turns  .

Adjust the linkage setting correction by turning nut (1) through 1.0 turns in + direction before resetting nut (2) and countering with 6 Nm.

Example 2:

Actual value measured by the diagnostic function: - 1, 5 mm  .

Required correction: -1.5 mm: 0.75 mm  = -2 turns.

Adjust the linkage setting correction by turning nut (2) through 2 turns in - direction before resetting nut (1) and countering with 6 Nm.

Check basic setting again using diagnosis.

Assemble engine.

Fig 1: Adjusting Electrical Controller Drive (Wastegate Valve)
G09846256Courtesy of BMW OF NORTH AMERICA, INC.