Condition for fault identification
Test condition:
The fault is recognized when the combustion stroke in a particular cylinder is slower than the combustion strokes on the other cylinders.
Potential problem source(s):
- Defect in mixture formation
- Defect in ignition system
- Mechanical defect
- Defective DME
Terminal condition: none
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
- None
Time condition:
- None
Other conditions:
- Engine ON