64 50... Instructions for handling refrigerant R 134a
Work on the refrigerant circuit may only be carried out by experts!
Installation
After each refill of an A/C system, check that the protective caps of the filler valves are hand-tight. They serve as additional seals.
Avoid all contact with liquid or gaseous R 134a. Wear protective goggles and gloves when working on the refrigerant circuit.
- Follow SAFETY INSTRUCTIONS for handling R134a refrigerant.
As a gas, R 134a is colorless, odorless and heavier than air. If it enters the atmosphere, this may result in an imperceptible danger of asphyxiation or in cardiac palpitations, especially in workshop pits. Ventilate rooms adequately; if necessary, turn on installed extractor systems.
Store charged refrigerant pressure flasks in a place where they are not exposed to direct sunlight or any other heat source (max. 45 °C). Also avoid exposing them to mechanical stress (e.g. by dropping).
Do not weld or solder on to filled A/C systems or in rooms into which R 134a may have leaked. Exposure to flames or high temperatures (≥ 50 °C) may give rise to toxic decomposition products (fluorine gas). For this reason, do not smoke either.
In the event of fire, carbon dioxide (CO2), extinguishing powder and a sprayed water jet are deemed to be suitable extinguishing agents. Cool reservoirs at risk with a sprayed water jet (risk of bursting!).
If the protective caps on the filler valves are difficult to open, there is a risk of injury from leaking valve inserts (high pressure).
The filled refrigerant circuit of the A/C system is subject to gauge pressure. Before carrying out repairs on the A/C system, it is absolutely essential to draw off the refrigerant.
- Before conducting repairs, check the actual pressure drop on the pressure gauge of the A/C service station.
R 134a must be drawn off, cleaned and returned to the A/C system using an A/C service station following the relevant operating instructions.
For a properly functioning A/C system, it is essential to have the greatest possible levels of cleanliness when working on the A/C system and the longest possible evacuation (at least 30 minutes dehumidification from refrigerant circuit) before each filling of the A/C system.
R 134a absorbs moisture very easily. Therefore, seal off opened pipes, condenser, evaporator, compressor and drier bottle immediately with plugs.
- If an air conditioning system has been emptied completely because of a leak, accident or in the course of a repair, the DESICCANT INSERT and
COMPLETE CONDENSER must be replaced, since too much moisture may penetrate the inside
With replacement parts, the plugs may only be removed immediately before the lines are connected. In the event of warranty claims, the old parts must be provided with plugs to be able to determine the cause of the damage.