LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2011 >> Z4 35is >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 24 (Cooling System - Repair (N52)) >> 1700 Coolant, Checking Cooling System >> 17 00 039 Venting and filling cooling system with vacuum filling unit (Version 1)

17 00 039 Venting and filling cooling system with vacuum filling unit (Version 1)

WARNING: This page is about a different variant/trim than selected.
SPECIAL TOOLS REFERENCE CHART

Type Engine Adapter Y from 17 0 100
E60/E61/E63/E64 All 17 0 113
E65/E66 M54/N52/N62/N62T/N73 17 0 105
E65/E66 M57S/M57T/M67/M67T 17 0 113
E70/E71/E72 All 17 0 113
E81/E82/E84/E87/E88/E89 All 17 0 113
E83 M54/N46/N52K 17 0 105
E83 M47S/M57S/M57T/M57Y/N47 17 0 113
E85/E86 All 17 0 105
E90/E91/E92/E93 All 17 0 113
F01/F02/F03/F04/F07/F10 All 17 0 113
R50/R52 W10 17 0 107 and 17 0 102
R50 W17 17 0 109
R52/R53 W11 17 0 109
R55/R56/R57/R60 All 17 0 109
F25 All 17 0 113
IMPORTANT: Lifetime coolant filling: 
Never reuse used coolant!
When replacing and removing components which rely on the corrosion protection effect of the coolant, it is essential to change the coolant. The cooling system must therefore be drained and refilled.
In the case of other removal work involving the draining of part quantities of coolant, replace these quantities which have been drained with new coolant.
IMPORTANT: You must protect the alternator against contamination by coolant when carrying out repair work on the cooling circuit.
Cover alternator with suitable materials.
Failure to comply with this procedure may result in an alternator malfunction.

Note on ordering:

IMPORTANT: Risk of slipping due to coolant on the floor.
Danger of injury! 

Catch and dispose of emerging coolant in drip tray (1) and if necessary special tool 00 2 030 (universal hydraulic lifting equipment).

Recycling: 

Observe country-specific waste disposal regulations.

Fig 1: Identifying Drip Tray And Special Tool (00 2 030)
G05476170Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: Check all the coolant hoses before filling the cooling system with the vacuum filling unit.
If necessary, replace damaged and porous coolant hoses.
Fig 2: Identifying Vacuum Filling Unit Components
G06889253Courtesy of BMW OF NORTH AMERICA, INC.

Requirements 

Select adapter (Y) according to table and connect to coolant expansion tank.

Connect filler unit to adapter connection (X).

Fig 3: Identifying Adapter And Adapter Connection
G06853591Courtesy of BMW OF NORTH AMERICA, INC.

Shut-off valves (A) and (B) of the filling unit (1) must be closed.

X) Expansion tank connection

Fig 4: Identifying Filling Unit Shut-Off Valves
G06853592Courtesy of BMW OF NORTH AMERICA, INC.

Connect venturi nozzle (1) to filling unit (2).

X) Expansion tank connection

Fig 5: Connecting Venturi Nozzle To Filling Unit
G06853593Courtesy of BMW OF NORTH AMERICA, INC.

Connect compressed air (1).

X) Expansion tank connection

Fig 6: Connecting Compressed Air Line
G06853594Courtesy of BMW OF NORTH AMERICA, INC.

Open shut-off valve (B).

The venturi nozzle produces a flow noise.

Fig 7: Opening Shut-Off Valve
G06853595Courtesy of BMW OF NORTH AMERICA, INC.

Then open shut-off valve (A) until the filling hose (1) is free of bubbles.

Close shut-off valve (A) again. The filling hose (1) is vented in this way.

Fig 8: Opening/Closing Of Shut-Off Valve
G06853596Courtesy of BMW OF NORTH AMERICA, INC.

Shut-off valve (B) remains open. Generate vacuum in coolant system for approx. 2 minutes. The final vacuum is reached at a vacuum of -0.7 to -0.95 bar. Green scale on the vacuum meter.

NOTE: The coolant hoses contract during vacuum build-up.

Then close shut-off valve (B) again.

Fig 9: Checking Shut-Off Valve Opening Time
G06853597Courtesy of BMW OF NORTH AMERICA, INC.

Both shut-off valves (A) and (B) must be closed. Then seal Venturi nozzle (1).

Fig 10: Closing Shut-Off Valve
G06853598Courtesy of BMW OF NORTH AMERICA, INC.

The cooling system must hold the vacuum for 30 seconds. If the needle in the vacuum meter falls, this indicates a leak in the cooling system.

If the vacuum remains constant, proceed with filling.

In event of leaks, check cooling system for leaks.

Fig 11: Identifying Vacuum Meters
G06853599Courtesy of BMW OF NORTH AMERICA, INC.
IMPORTANT: There must be sufficiently premixed coolant in the filling unit container, 1 - -2 liters more than the vehicle filling capacity.

Position the filling unit container at the same height as the coolant expansion tank.

Shut-off valve (B) remains closed during the filling process.

To fill the cooling system, open shut-off valve (A) to filling unit container.

Fig 12: Opening Shut-Off Valve To Filling Unit Container
G06853600Courtesy of BMW OF NORTH AMERICA, INC.

Coolant is now added.

The filling process is finished when the needle in the vacuum meter is at 0 bar or no longer falls.

If necessary, reduce remaining vacuum. Open shut-off valve (B) to do so.

Fig 13: Filling Coolant
G06889264Courtesy of BMW OF NORTH AMERICA, INC.

Remove filling unit with adapter from expansion tank.

Adjust coolant level to max.

Close coolant expansion tank.

Fig 14: Adjusting Coolant Level To Max
G06853602Courtesy of BMW OF NORTH AMERICA, INC.

Check function of cooling system.

Check cooling system for leaks.