12 14 521 Replacing crankshaft pulse generator (N54)
IMPORTANT:
Read and comply with notes on ESD PROTECTION (ELECTRO STATIC DISCHARGE)
.
IMPORTANT:
Aluminum screws/bolts must be replaced each time they are released.
Aluminum screws/bolts are permitted with and without color coding (blue).
For reliable identification:
Jointing torque and angle of rotation must be observed without fail (risk of damage).
Necessary preliminary tasks
- Read out fault memory of DME control unit
- Switch off ignition
NOTE:
Installation location of pulse generator for crankshaft is underneath starter motor.
Detach plug (1) from crankshaft pulse generator (2).
Release screw.
Installation:
Replace aluminum screws.
Tightening torque 13 62 4AZ .
Withdraw pulse generator (2) from crankcase.
Installation:
Replace sealing ring.
NOTE:
Check stored fault messages.
Now clear the fault memory.