LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2011 >> X6 ActiveHybrid >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating And Air Conditioning - Repair (ACTIVEHYBRID) >> Heater With Operation >> 64 11 273 Replacing water valve for heating unit

64 11 273 Replacing water valve for heating unit

WARNING: Scalding hazard!
Work on the cooling system may only be carried out when it has cooled down.
Follow INSTRUCTIONS for working on cooling system.
NOTE: CLAMP OFF  coolant hoses on water valve.

Recycling:

Coolant emerges when coolant lines are detached. Have a suitable collecting container ready.

Catch and dispose of escaping coolant.

Observe country-specific waste-disposal regulations.

Necessary preliminary tasks:

N54 Only: 

N63 only: 

NOTE: Engine is shown removed for purposes of clarity.

Disconnect plug connection (1).

Release hose clamps (2, 3) and detach coolant hoses.

Installation: 

Do not  mix up connections of coolant hoses.

Replace damaged coolant hoses.

Fig 1: Identifying Plug Connection And Hose Clamps
G04792584Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

To avoid the buildup of noise, make sure that the rubber mounts (1) on the water valve are securely seated in the mounting on the frame side member (2).

Fig 2: Identifying Rubber Mounts And Frame Side Member
G04727813Courtesy of BMW OF NORTH AMERICA, INC.

After installation: