Action in service
- Unplug all components on the BSD with the exception of the oil condition sensor, clear diagnostic fault codes from the control module fault memory and then ignition off/on. If the diagnostic fault code is logged again this means that the oil condition sensor is defective.
- Reconnect all of the remaining devices on the BSD one after the other, clear the control module fault memory, and then switch the ignition off/on, continuing until the defective component is found.
- If the fault is not found, check the BSD.
- If the fault appears sporadically then check all contacts on the BSD.