Condition for fault identification
Test condition:
The fault is recognized when communications with the EGS electronic gearbox control on the A and PT CAN break down.
Potential problem source(s):
- Interference in communications to EGS via A and PT CAN
Terminal condition: Terminal 15
Voltage condition:
- Electrical system voltage > 10 V
Temperature condition:
- None
Time condition:
- 750 sec.
Other conditions: