12 14 522 Replacing pulse generator on left inlet camshaft (N63): Notes
(cylinder bank 5 to 8)
Necessary preliminary tasks:
- Read out fault memory of DME control unit; if necessary, work through test schedules
- Switch off ignition
- Remove left intake filter housing , see 13 71 030 REMOVING AND INSTALLING BOTH INTAKE FILTER HOUSINGS (N63) .
Unlock plug (1) and remove.
Release screw (2).
Tightening torque 13 62 3AZ, see 13 62 SENDERS FOR CONTROL UNIT .
Remove pulse generator (3).