Necessary preliminary work
- Read out fault memory in DME control unit
- Switch off ignition
- Remove right INTERCOOLER
- Release holder for electropneumatic pressure converter (EPPC) and carefully press to one side
NOTE:
Solenoid valve (4) controls the inlet adjustment unit.
Solenoid valve (2) controls the exhaust adjustment unit.
Solenoid valve (2) controls the exhaust adjustment unit.
Unlock plug connections of solenoid valves (2 and 4) and disconnect.
Installation note:
Plug connections must snap audibly into place!
Unfasten screws (1 and 3).
Tightening torque 11 36 3AZ .
Pull out solenoid valves (2 and 4).
Installation note: