Necessary preliminary work
- Remove right CYLINDER HEAD COVER
- Remove FAN COWL with electric fan
- Remove BELT PULLEY for air conditioning system
- Remove right CHAIN TENSIONER
Mount special tool 11 9 900 at position of chain tensioner.
Preload hexagon socket screw with special tool 00 9 250 to 0.6 Nm.
NOTE:
Marking (MP = Mounting Position) is important for installing special tool 11 8 570
.