17 00 039 Venting cooling system and checking for watertightness
Open sealing cap only after engine has cooled down.
In the case of other removal work involving the draining of part quantities of coolant, replace these quantities which have been drained with new coolant.
Only when refilling!
Use only recommended COOLANT .
Observe appropriate water/antifreeze mixture ratio.
Perform filling operation slowly.
Adjust coolant level to maximum.
Close coolant expansion tank.
Installation note:
Close the sealing cap (1) until the arrows line up.
Adding coolant:
Cooling system must be filled with a VACUUM FILLING UNIT only!
Use only recommended COOLANT .
Observe appropriate water/antifreeze mixture ratio.
Observe FILLING CAPACITIES .
Bleed cooling system!
Switch on the low-beam headlights to perform the bleeding procedure. If the low-beam headlights are not switched on, the ignition (Terminal 15) will switch off automatically after a certain period of time and interrupt the bleeding procedure.
- Connect battery charger.
- Switch the ignition on.
- Switch on low-beam headlight.
- Set heating to maximum temperature. Take back blower to smallest stage.
- Driving experience switch must not be set to ECO PRO!
- Press accelerator pedal for 10 seconds to floor. Engine must not be started.
- The bleeding procedure was started by pressing the accelerator pedal and takes approx. 12 mins. (the electrical coolant pump was activated and switches off automatically after approx. 12 mins.).
- Then adjust fluid level in the coolant expansion tank to maximum.
- Check the coolant system for LEAKS .
- If the ventilation has to be performed again, deactivate DME completely (remove ignition key for approx. 3 minutes). Then repeat from point 3.
Close coolant expansion tank.
Installation note:
Close the sealing cap (1) until the arrows line up.