64 50... Instructions for handling refrigerant oil (for refrigerant R 134a)

WARNING: Observe the following points when handling refrigerant oil:
  • Wear protective goggles.
  • Wear protective gloves made from impermeable plastic.
  • Do not swallow.
  • Do not inhale.

Action to be taken after contact with refrigerant oil:
  • After contact with eyes, rinse thoroughly with plenty of water and take out contact lenses (if worn). Then seek immediate medical attention.
  • After contact with the skin, wash body parts affected with plenty of soap and water.
  • Do not induce vomiting if oil is swallowed, seek immediate medical attention.
  • If inhaled, introduce the person affected to fresh air. Seek medical attention if problems persist.
WARNING: refrigerant oil is non-combustible and non-explosive at normal temperatures. In spite of this, the following precautions must be observed:
  • Do not store in the vicinity of flames, heat sources or strongly oxidizing materials.
  • Suitable extinguishants: Carbon dioxide (CO2 ), dry extinguishant, foam.
IMPORTANT: refrigerant oil is hygroscopic and must therefore be stored in suitable containers that are sealed airtight!

Recycling: 

Dispose of drawn-off refrigerant oil as hazardous waste.

Observe country-specific waste disposal regulations.

Absorb escaping refrigerant oil with fluid-binding material.

Notify the relevant authorities if larger amounts of refrigerant fluid are discharged into aboveground water supplies, drainage systems or subsoil.