Home >> BMW >> 2011 >> 335i 2D Convertible, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (General Electrical System - Repair - E90) >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Opening plug housings and removing contacts of different plug systems >> 61 13... Socket housing (radio plug), Hybrid System MQS/MPQ >> Removing MQS contacts from contact carrier

Removing MQS contacts from contact carrier

WARNING: This page is about a different variant/trim than selected.

Press lock (1) in direction of arrow and pull housing (2) out of radio plug.

Fig 1: Pressing Lock In Direction Of Arrow And Pull Housing Out Of Radio Plug
G04727546Courtesy of BMW OF NORTH AMERICA, INC.

Press lock (1) in direction of arrow. Pull contact carrier (2) out of housing (3).

NOTE: When the contact carrier is pulled out, the secondary locks of the socket contacts are raised.
Fig 2: Pulling Contact Carrier Out Of Housing
G04727547Courtesy of BMW OF NORTH AMERICA, INC.

Hold down retaining hook (1) of socket contact in opening of contact carrier with a small screwdriver.

Pull wire with socket contact in direction of arrow as far as secondary lock (2).

NOTE: The illustration shows an 8-pin female connector housing where contact removal is identical.
Fig 3: Pulling Wire With Socket Contact In Direction Of Arrow Secondary Lock
G04727548Courtesy of BMW OF NORTH AMERICA, INC.

Depress retaining hook in secondary lock (1) once again. Remove wire with female contact (2) from contact carrier (3) completely.

Fig 4: Depressing Retaining Hook In Secondary Lock
G04727549Courtesy of BMW OF NORTH AMERICA, INC.