LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2011 >> 335i 2D Convertible, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (General Electrical System - Repair - E90) >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Cutting off, stripping insulation and cutting optical fibres to length >> Stripping insulation from optical fibre

Stripping insulation from optical fibre

WARNING: This page is about a different variant/trim than selected.

Open hand pliers (1).

Open lever (2) in direction of arrow.

Fig 1: Identifying Hand Pliers And Lever
G04727527Courtesy of BMW OF NORTH AMERICA, INC.

Slide optical fibre (1) into stripping device (2) until flush at point (3).

Close hand pliers (4) fully.

Close clamping lever (5) in direction of arrow.

Open hand pliers (4) by one tooth notch.

Open clamping lever (5) against direction of arrow again and remove optical fibre (1).

NOTE: A stripping replacement blade set is available under number 61 4 327.
Fig 2: Sliding Optical Fiber Into Stripping Device
G04727528Courtesy of BMW OF NORTH AMERICA, INC.