LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2011 >> 335i 2D Convertible, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (General Electrical System - Repair - E90) >> Plug Connection, Terminal, Power Distribution Box >> 61 13... Crimping Micro Quadlock System contacts (MQS)

61 13... Crimping Micro Quadlock System contacts (MQS)

WARNING: This page is about a different variant/trim than selected.

Special tools required: 

To crimp MPQ contacts, use pliers 61 4 321 (1) in conjunction with crimping head 61 4 324 (2) from crimping set 61 4 320 .

NOTE: Pliers (1) open automatically as far as they will go when handles are pressed together.
Fig 1: Crimping MPQ Contacts Using Pliers 61 4 321
G04727516Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Fold up contact carrier (2).

Insert MQS contact (3) in contact carrier (2).

Fold back contact carrier (2).

Fig 2: Inserting MQS Contact In Contact Carrier
G04727517Courtesy of BMW OF NORTH AMERICA, INC.
NOTE: Follow procedure for CUTTING AND STRIPPING INSULATION  from cables.

Close pliers (1) one notch.

Insert stripped cable (2).

Close pliers (1) fully.

Fig 3: Inserting Stripped Cable
G04727518Courtesy of BMW OF NORTH AMERICA, INC.

Open pliers (1).

Open contact carrier (2) gently and carefully remove MQS contact.

Fig 4: Opening Contact Carrier Gently
G04727519Courtesy of BMW OF NORTH AMERICA, INC.