Condition for fault identification
Test condition:
The fault is recognized when the pressure level in the high-pressure system is 3.5 bar lower than the specified value.
Potential problem source(s):
- Fuel tank empty
- Defective rail-pressure sensor
- Defect in low-pressure system
- High-pressure pump defective
Terminal condition: Terminal 15
Voltage condition:
- Onboard electrical system voltage between 9 V and 16 V
Temperature condition:
None
Time condition:
- None
Other conditions:
- None