67 62 000 Removing and installing or replacing flat motor for front left or right power window regulator
Necessary preliminary tasks:
- Detach SOUND INSULATION from front door in working area
Disconnect plug connection (1).
Release screw (3) and remove holder (2).
Release screws (4) and remove flat motor (5).
Tightening torque 67 62 1AZ .
Installation note:
Mount flat motor (5) precisely on gearing of power window regulator.
Replacement:
PERFORM normalization procedure