Condition for fault identification
Test condition:
The fault is recognized when the actual pressure in the low-pressure fuel system is unable to remain within the specified limits when trailing the specified pressure.
Potential problem source(s):
- Collateral fault
- Defect in low-pressure sensor
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- 20 °C < coolant temperature < 105 °C
Time condition:
- 10 sec. after engine on
Other conditions:
- Engine on