Condition for fault identification
Test condition:
The fault is recognized when the voltage of an oxygen sensor behind catalytic converter is greater than 0.669 V while the voltage of the other oxygen sensor is simultaneously less than 0.2 V.
Potential problem source(s):
- Oxygen sensors behind catalytic converter interchanged.
Terminal condition: none
Voltage condition:
- None
Temperature condition:
- Engine temperature > 85 °C
Time condition:
- None
Other conditions:
- Engine on