Repair procedures (plant/service)
This malfunction is detected during the active test. The active test is triggered by the trim control diagnosis function (trim controller fault code stored in the control module's fault memory!)
- Initiate system test for reversed O2 sensors. Follow instructions for system test.
- If the system test fails to produce a result then.
- Visual inspection of wiring and plugs.
- Electrical check of wiring.
- Replace wires or plugs as indicated.
- Check exhaust system upstream from downstream (post-cat) O2 sensor for leaks.
- Replace downstream (post-cat) O2 sensor
- Replace upstream (pre-cat) O2 sensor
- Replace control module