11 36 575 Replacing solenoid valve for exhaust side on VANOS adjustment unit
WARNING: This page is about a different car, the 2002 BMW Z3 and 2001 BMW Z3. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
For Special Tool identification, see SPECIAL TOOLS - Z3 .
Special Tools Required:
- 11 6 420
Necessary Preliminary Tasks:
- Read out fault memory of DME control unit.
- Check stored fault messages.
- Switch off ignition.
Unlock plug (1) and remove.
Cut through cable tie (2).
NOTE:
Once it has been removed, oil drips from the solenoid valve. Have a cleaning cloth ready. Make sure no oil drips onto the belt drive. Remove any remnants of oil immediately with cleaning cloth.
Release solenoid valve with special tool 11 6 420.
Installation:
Tightening torque, refer to 11 36 1AZ in VARIABLE CAMSHAFT TIMING .
Now clear the fault memory.