LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> X5 48i >> Repair and Diagnosis >> External Pages >> Different car >> Section 411 (General Electrical System - Service Techniques) >> Power supply E60, E61, E63, E64 >> Brief description of components >> Micro-Power Module: E60, E61, E63, E64

Micro-Power Module: E60, E61, E63, E64

WARNING: This page does not describe the selected car, but rather 21 other vehicles, including the 2006 BMW Z4, 2006 BMW M3, 2006 BMW M Roadster, 2006 BMW M Coupe, and 2006 BMW 550i. However, it is still accessible from the selected car via links, so may be relevant.

Installation location 

> up to 09/2005: The micro-power module (MPM) is located in the spare-wheel well.

> From 09/2005: The MPM function is integrated into the body-gateway module (KGM).

Example: E60 until 09/2005

Fig 1: Locating Micro-Power Module: E60, E61, E63, E64
G00432693Courtesy of BMW OF NORTH AMERICA, INC.
MICRO-POWER MODULE: E60, E61, E63, E64

Item Description Item Description
1 Micro-power module (MPM) 2 Battery
3 PDC control unit (Park Distance Control)    

Construction 

Example: E60 until 09/2005

Fig 2: Identifying Micro-Power Module Construction: E60, E61, E63, E64
G00432694Courtesy of BMW OF NORTH AMERICA, INC.

A 15-pin connector links the MPM to the vehicle electrical system and the K-CAN. The K-CAN connection allows the exchange of CAN messages between the control units of the body electronics.

PIN ASSIGNMENT X16021, 15-PIN MULTI-PIN CONNECTOR

Pin Type Description
1 --- ---
2 --- ---
3 E/A K-CAN Low
4 M Earth
5 --- ---
6 --- ---
7 E Continuous positive
8 E Input power supply from rear fuse carrier
9 --- ---
10 --- ---
11 E/A K-CAN High
12 --- ---
13 --- ---
14 E Terminal 15
15 A Output power supply for terminal 30g-f
  A = Output
E = Input
E/A = Input and output
M = Earth
V = Supply
For current specifications regarding pin assignments, please refer to BMW diagnosis system

How it works 

The micro-power module (MPM) enables consumers to be switched off in a defined manner if a fault develops while the vehicle is out of use. The MPM is linked with other control units in the vehicle to allow it to transmit and receive CAN messages via the K-CAN. The MPM has a bistable relay which controls terminal 30g-f. If the MPM detects a fault, the relay will switch terminal 30g-f off. The reason for the deactivation will be stored in the MPM. The following consumers are connected to terminal 30g-f:

Conditions required for switch-on 

The switch-on conditions for the bistable relay are:

The MPM is woken up by activity in the K-CAN. After being "woken up", the bistable relay returns to the switch state it was in before it was "woken up".

Conditions required for switch-off: 

The switch-off conditions for the bistable relay are:

The MPM goes into sleep mode approx. 1 second after the K-CAN goes into sleep mode. Before the MPM goes into sleep mode, the current switch state of the bistable relay is stored.