LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> X5 48i >> Repair and Diagnosis >> External Pages >> Different car >> Section 403 (Heating And Air Conditioning - Repair) >> Air Conditioning System >> 64 50 ... Leak-testing with leak tester device

64 50 ... Leak-testing with leak tester device

WARNING: This page does not describe the selected car, but rather 12 other vehicles, including the 2010 BMW M6, 2010 BMW 650i, 2009 BMW M6, 2009 BMW 650i, and 2008 BMW M6. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Avoid contact with refrigerant. Follow safety precautions when handling refrigerant, refer to 64 50 ... SAFETY INSTRUCTIONS FOR HANDLING REFRIGERANT R 134A .

Carry out leak-testing with a leak tester device from the workshop equipment catalog following the device manufacturer's operating instructions.

If leaks not to be localized are already identified during evacuation, the A/C system must nevertheless be filled, refer to 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A) . Then test for leaks with leak tester device.

NOTE: Refrigerant is heavier than air.

Therefore always conduct the leak test below the lines and components to be tested.

Shield lines and components against strong blasts of air (wind, drawing off).

Tighten down loose lines, mark leaks.

Then draw off draw off A/C system, refer to 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A) , and seal off or repair leakage points.

Then refill A/C system and test for leaks, refer to 64 50 009 DRAWING OFF, EVACUATING AND FILLING A/C SYSTEM (R 134A) .