Repair procedures (plant/service)
Conduct start data calibration; start engine, n >2000 rpm for 10 sec.; engine OFF, but Terminal R remains on; restart engine when wait-state phase elapses; if engine fails to start WC in CAS does not proceed with switching sequence: Continue problem diagnosis with CAS