LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> X5 35d >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Engine Electrical System - Repair (N52)) >> Starter Lead >> 12 42 500 Removing and Installing Or Replacing Battery Positive Lead (between Starter, Alternator And Battery Positive Terminal)

12 42 500 Removing and Installing Or Replacing Battery Positive Lead (between Starter, Alternator And Battery Positive Terminal)

WARNING: This page is about a different variant/trim than selected.

Necessary preliminary tasks: 

Open cover.

Release nut, remove battery positive lead (1) from battery positive terminal.

Tightening torque. See 12 42 STARTER CABLE .

Release nut and remove battery positive lead (1) from alternator. Tightening torque 12 31 1AZ. See 12 31 ALTERNATOR WITH DRIVE AND MOUNTING PARTS

Unlock plug (1) and remove.

Unfasten nut.

Tightening torque 12 41 3AZ. See 12 41 STARTER MOTOR WITH MOUNTING

Detach battery positive lead (2) from starter motor and remove.

NOTE: Check stored fault messages. Now clear the fault memory.
Fig 1: Identifying Cover
G04793923Courtesy of BMW OF NORTH AMERICA, INC.