LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> X5 35d >> Repair and Diagnosis >> External Pages >> Different car >> Section 2104 (Distance Systems, Cruise Control - Repair) >> Night Vision >> 66 53 010 Calibrating reversing camera

66 53 010 Calibrating reversing camera

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2014 BMW X6, 2013 BMW X6, 2012 BMW X6, 2011 BMW X6, and 2010 BMW X6. However, it is still accessible from the selected car via links, so may be relevant.
WARNING: Risk of injury!
Laser radiation at adjustment unit.
Do not look into the beam!
Laser class 2
As per EN 60825-1: 1994
P ≥ 1 mW
Lambda = 632.8 nm
NOTE: Calibration of reversing camera must be carried out after the following work:
  • Removal and installation/replacement of reversing camera
  • Body repair work at rear end of vehicle
  • Adjustment of rear lid
IMPORTANT: Follow instructions and specifications in test module. 
To obtain an optimum result, always adhere to the following conditions:
  • Vehicle standing level on headlight aiming station
  • Correct tire inflation pressure (see instruction plate on car).
  • Vehicle is free of load
  • Rear seat bench is unoccupied
  • Do not swap seats during calibration
  • Steering wheel in straight-ahead position
  • Do not move steering wheel
NOTE: Once the laser has been aligned to the camera lens, it is necessary to calibrate the reversing camera via the DIS Tester. Also switch on reversing camera by means of PDC button. Calibration can only be carried out with the BMW diagnosis system.

Service functions:

Observe information on use of CORGHI KDS quick-action clamp  , see 66 53... Instructions for adapting adjustment unit for reversing camera (CORGHI KDS quick-action clamp) .

Secure KDS quick-action clamp on rear wheels on both sides.

Insert ball pivot (1) in guide (2) up to stop and secure with screw (3).

Fig 1: Identifying Ball Pivot And Guide
G06213954Courtesy of BMW OF NORTH AMERICA, INC.
Fig 2: Identifying Longitudinal And Transverse Rod Dimensions
G06213955Courtesy of BMW OF NORTH AMERICA, INC.

Dimension (A) of longitudinal rod (1) and dimension (B) of transverse rod (2) must be adapted to the type of vehicle on both sides, see 66 53 REVERSING CAMERA (RFK) E70 or 66 53 REVERSING CAMERA (RFK) E71 .

Position target (1) on transverse rod with scale and align to zero point on scale (2).

Secure target (1) using knurled screws (3).

Fig 3: Positioning Target On Transverse Rod
G06213956Courtesy of BMW OF NORTH AMERICA, INC.
Fig 4: Positioning Laser Point
G06213957Courtesy of BMW OF NORTH AMERICA, INC.

Switch on laser pointer (2) with knurled screw (1).

Align laser pointer first to zero point on scale (3), then upwards to center of BMW badge (4).

In the event of a laser deviation from the BMW badge center, this must be compensated for by shifting the complete linkage in the corresponding direction.

After realigning the target, check the position of the laser again and correct if necessary.

Align contact surface (1) on both sides to tire side wall.

Tighten linkage simultaneously on both sides with adjusting screw (2).

NOTE: After securing linkage, check position of laser pointer again on vehicle's BMW badge. If necessary, correct by means of adjusting screws.
Fig 5: Identifying Contact Surface And Adjusting Screw
G06213958Courtesy of BMW OF NORTH AMERICA, INC.

Slacken knurled screws (2).

Adjust scale value (1) as specified. 

Tighten down knurled screws (2).

Version with ride-height control: 

Start calibration of reversing camera by way of BMW diagnosis system.

Fig 6: Adjusting Scale Value
G06213959Courtesy of BMW OF NORTH AMERICA, INC.