Bleeding front-axle brake circuit

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2014 BMW X6, 2013 BMW X6, 2012 BMW X6, 2011 BMW X6, and 2010 BMW X6. However, it is still accessible from the selected car via links, so may be relevant.

Connect bleeder hose with collecting tray to bleeder valve on front right brake caliper.

Close bleeder valve.

Run bleeding routine with DIS with bleeder valve open.

After completing routine, press brake pedal 5 times to floor, clear and bubble-free brake fluid must flow out.

Close bleed valve.

Repeat procedure at front left.

Fig 1: Connecting Bleeder Hose With Collecting Tray To Bleeder Valve On Front Right Brake Caliper
G04726565Courtesy of BMW OF NORTH AMERICA, INC.

Switch off brake fluid changer and remove from expansion tank.

Check brake fluid level. If necessary, top up/draw off to max. level.

Close expansion tank.

NOTE: Pay attention to rubber seal (1) in sealing cap.
Fig 2: Checking Brake Fluid Level
G04726566Courtesy of BMW OF NORTH AMERICA, INC.