51 71 372 Removing And Installing/Replacing Both Tension Struts On Spring Strut Domes
Necessary preliminary tasks:
Right side:
- Remove microfilter housing . See 64 31 081 REMOVING AND INSTALLING/REPLACING MICROFILTER HOUSING .
Left side:
- Remove left/right microfilter housing covers . See 64 31 101 REMOVING AND INSTALLING/REPLACING LEFT MICROFILTER HOUSING COVER or 64 31 106 REMOVING AND INSTALLING/REPLACING RIGHT MICROFILTER HOUSING COVER .
Remove seal (1) for engine hood/bonnet.
Release screws (2, 4).
Remove partition wall (3).
Installation:
Make sure partition wall is correctly positioned.
Right side:
Release clip (1).
Release screws (2).
Remove partition wall (3).
Installation:
If necessary, replace faulty clip (1).
Make sure partition wall is correctly positioned.
Make sure bolts are installed in correct positions.
Left side:
Release clip (1).
Release screws (2, 4).
Unclip connecting cable (3).
Remove partition wall (5).
Installation:
If necessary, replace faulty clip (1).
Make sure partition wall is correctly positioned.
Make sure bolts are installed in correct positions.
Release screws (1).
Remove tension strut (2).
Replace screws.
Tightening torque. See BODY EQUIPMENT - TIGHTENING TORQUES .