Safety functions
- Block detection for mirror folding function:
Each door module has lock detection to protect the motors from overload.
If the drive is obstructed, the current in the motor increases. The door modules compare the starting current in normal operating mode with the current in the obstructed drive. An obstruction is detected by any difference in the current. The motor is no longer driven.
- Repeat lock:
To provide overheating protection for the motor the mirror folding function is locked after it has been working for a total of 45 seconds.
If the repeat lock is active, the door mirrors can be unfolded once more.
- Undervoltage shutdown:
The power supply to the door mirrors is monitored in the door module. All door mirror functions are locked if the voltage drops below 8.5 V. The functions are available again when the voltage rises above 9 V.