67 62 000 Removing and installing or replacing flat motor for front left or right power window unit
WARNING: This page is about a different car, the 2013 BMW X5 M, 2012 BMW X5 M, 2011 BMW X5 M, and 2010 BMW X5 M. However, it is still accessible from the selected car via links, so may be relevant.
Necessary preliminary tasks
- Remove SOUND INSULATION IN FRONT DOORS .
- Remove FRONT SECTION OF POWER WINDOW UNIT .
Release screws (1) and detach flat motor (2) from power window unit.
Installation:
Retaining pins (3) must not be released!
IMPORTANT:
To ensure tension-free installation of flat motor, observe the specified screwing sequence without fail.
Tighten first screw (1), then screw (2) and finally screw (3).
Tightening torque 67 62 1AZ .
After installation
A normalization must be carried out in order to activate anti-trapping protection.
Normalization sequence:
- Ensure adequate system voltage.
- All doors closed.
- Press correspond power window switch in "Close" position and hold for approx. 2 seconds with window closed.
NOTE:
If normalization is unsuccessful or the power window unit malfunctions, it will be necessary to carry out normalization via the control unit functions in the diagnosis system.
- Front power window: Footwell module.
- Rear power window: Junction box.