64 50... Leak detection with ultraviolet additives (UV additives) (BMW leak-testing case)
Observe national regulations in all other countries!
Read and comply with the instructions for use provided with the special tool particularly with regard to accident prevention, health protection and environmental protection.
Use only BMW-approved UV additives (e.g. TRACER).
Only the basic procedure is described in the following!
FOLLOW SAFETY PRECAUTIONS WHEN HANDLING REFRIGERANT .
Do not use the ultraviolet lamp without the filter glass.
Eyes and skin will suffer damage if the ultraviolet lamp is used without the filter glass.
When using the UV lamp, wear the safety goggles provided in the case.
- Fill the hose system of the hand pump completely with UV additive PRIOR to use.
- Use the UV additive exclusively for refrigerant oil approved by BMW.
- Do not operate the air conditioning system while the hand pump is connected or in use.
- The air conditioning system must always be filled with an adequate amount of refrigerant to enable the leak-detecting agent to be properly distributed.
Necessary preliminary tasks
Before actually testing for leaks, check the entire refrigerant circuit using the UV leak detection lamp to ensure that no UV additive is already in the area of the refrigerant circuit.
If already illuminated areas are found, carefully clean the area in question with the cleaning agent contained in the case.
On initial use:
Connect hand pump (1) to additive cartridge (2) and hose piece (3).
On initial use:
Attach vent valve (1) to quick-release coupling (2).
Turn handle (3) on hand pump to advance the piston until a small amount of UV additive emerges. This vents the hose system.
Attach quick-release coupling (1) to low-pressure connection (2) of air conditioning system.
Turn handle on hand pump (3) until the required amount of UV additive is added.
The quantity of UV additive to be added is dependent on the AMOUNT OF REFRIGERANT IN THE REFRIGERANT CIRCUIT :
- Air conditioning systems with refrigerant filling up to 900 g: one graduation mark (4) on additive cartridge.
- Air conditioning systems with refrigerant filling in excess of 900 g: two graduation marks (4) on additive cartridge.
Further tasks:
- Start engine
- Run air conditioning system at highest stage for 5 - 10 minutes in order to ensure adequate distribution of dye in the system
- Turn off engine.
- Check all air conditioning system components for possible leaks
- Possible leaks show up in luminous green
Complete accompanying information label (1) with the relevant data and attach in an easily visible position next to the filling capacity information label (2).