Home >> BMW >> 2009 >> 650i 2D Convertible, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 3021 (General Electrical System - Repair) >> Battery >> 61 20 503 Vehicle battery - closed-circuit current monitoring

61 20 503 Vehicle battery - closed-circuit current monitoring

WARNING: This page is about a different car, the 2013 BMW X5 M, 2012 BMW X5 M, 2011 BMW X5 M, and 2010 BMW X5 M. However, it is still accessible from the selected car via links, so may be relevant.

Necessary preliminary tasks:

To access negative lead of battery, perform the necessary preliminary work described in DISCONNECTING NEGATIVE BATTERY CABLE .

Do not disconnect negative lead of battery. 

Connect BMW diagnosis system.

Connect clip-on probe to negative lead of battery. The arrow on the current clamp must point towards the battery.

Measure closed-circuit current.