LEMON Manuals: Even more car manuals for everyone
Home >> BMW >> 2009 >> 650i 2D Convertible, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 2052 (Engine - Repair (N63)) >> Emission Control Oxygen Sensor >> 11 78 543 Replacing right monitor sensor (N63)

11 78 543 Replacing right monitor sensor (N63)

WARNING: This page does not describe the selected car, but rather 7 other vehicles, including the 2014 BMW X6, 2013 BMW X6, 2012 BMW X6, 2011 BMW X6, and 2010 BMW X6. However, it is still accessible from the selected car via links, so may be relevant.

Special tools required: 

See ENGINE - SPECIAL TOOLS (N54, N63) .

WARNING: Scalding hazard! 

Only perform this work after engine has cooled down.

Necessary preliminary tasks: 

Release retaining clip (1).

Remove heat shield (2) over oxygen sensor.

Detach oxygen sensor cable from retaining clips (3).

Fig 1: Identifying Wire Ring And Retaining Clip
G06178811Courtesy of BMW OF NORTH AMERICA, INC.

Release monitor sensor (1) with special tool 11 7 020.

Fig 2: Removing/Installing Control Sensor
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

The threads of new lambda control/monitor sensors are already coated with Never Seez Compound.

If a lambda control/monitor sensor is to be reused, apply a thin and even coating of Never Seez Compound to the thread only.

The part of the lambda control/monitor sensor which projects into the exhaust system branch (sensor ceramics) must not  be cleaned and not  coated with lubricant.

Secure monitor sensor (1) with special tool 11 7 020.

Tightening torque 11 78 1AZ, see EMISSION CONTROL

Fig 3: Removing/Installing Control Sensor
G06178832Courtesy of BMW OF NORTH AMERICA, INC.

Installation: 

Check function of DME control unit.

Pay attention to cable routing of monitor sensor.